Beamline Summary
| Port | Short Name | Beamline Name | Energy Range | Instrument | Contact Person | 
|---|---|---|---|---|---|
| 1A | IR | Infrared Spectromicroscopy | 400–11700 cm-1 | Nicolet FT-IR & microscope / 2D mapping spatial resolution 10 µm | Orhan Kizilkaya | 
| 1B | DPC | Diagnostic Pinhole Camera | |||
| 2A | WL | White Light | |||
| 3A1 | WS-DCM | Wavelength Shifter (WS) Double-Crystal Monochromator for X-ray Diffraction & Powder Diffraction | 7 – 18 keV | XAS transmission, fluorescence, electron yield, XANES, EXAFS | Amitava Roy | 
| 3A2 | WS-XRD | WS X-ray Diffraction | 7 – 18 keV | Huber four-circle goniometer | |
| 3A3 | WS-SAXS | WS Small Angle X-ray Scattering | 11.9 keV | XENOCS SAXS-WAXS-GISAXS | Miriam Siebenbuerger | 
| 3B1 | 3-m NIM | 3-meter Normal Incidence  Monochromator  | 
                           
                           9-28 eV | ARUPS endstation LEED, 200 mm Scienta | Orhan Kizilkaya | 
| 3B1 | 3-m NIM |  3-m NIM Second tail  | 
                           
                           9-28 eV | Photoionization studies | Orhan Kizilkaya | 
| 4A | VLSPGM | Variable-Line-Spaced Plane Grating  Monochromator  | 
                           
                           200 eV –1.2 keV | NEXAFS, XAS, SR-XPS | Orhan Kizilkaya | 
| 4B | 5-m TGM | 5-meter Toroidal Grating | 20-300 eV | Omicron 150 mm, LEED, film prep, surface science | Orhan Kizilkaya | 
| 5A1 | MPW- Biomed-Tomo  | 
                           
                           Multipole Wiggler µ-tomography, X-ray phase contrast & medical physics | 35 – 60 keV | Biomed, tomography (2.5µm), X-ray phase contrast imaging, cell irradiation | Kyungmin Ham | 
| 5A2 | MPW-PwX | 
                              
                               Multipole Wiggler Probe with X-rays  | 
                           
                           
                              
                               7 – 15  | 
                           
                           macromolecular crystallography, XANES, XRD | Amitava Roy | 
| 5A3 | MPW-HEXAS | Multipole Wiggler High-Energy X-ray Absorption Spectroscopy | 4.5-25 keV | XAS transmission, fluorescence, electron yield, XANES, EXAFS | Amitava Roy | 
| 5B | DCM | Double-Crystal Monochromator | 1.8 – 6 keV  | 
                           
                           XAS transmission, fluorescence, e-yield | Amitava Roy | 
| 6A | LEXAS | Low Energy X-ray Absorption Spectroscopy | 
                              
                               1.2 - 1.8 keV  | 
                           
                           XAS transmission, fluorescence, electron yield, XANES | Amitava Roy | 
IR, Vacuum UV, & Soft X-ray
3-meter Normal Incidence Monochromator (NIM), Port 3B, 70 mrad
- High-resolution, high-flux beamline, range 2 - 50 eV, 
resolving power 10,000 (high energy) - 50,000 (low energy) - Dedicated SES-200 analyzer endstation for ARUPS measurement.
 - A “second tail” allows deflection of the highly resolved monochromatic beam to a second, user-selected or provided, endstation.
 - View High Resolution Photoemission of Organic Systems at 3m NIM Beamline at CAMD for more details.
 - Orhan Kizilkaya, orhan@lsu.edu
 
Varied-Line-Space Plane Grating Monochromator Beamline (VLSPGM), Port 4A, 7 mrad
- High-resolution soft x-ray beamline, range 200 -1200 eV
 - Resolving power 5000
 - NEXAFS, XAS, MCD measurements
 - View Upgraded varied-line-space PGM beamline at CAMD for more details.
 - Orhan Kizilkaya, orhan@lsu.edu
 
5-meter Toroidal Grating Monochromator Beamline (5m-TGM), Port 4B, 6 mrad
- High-resolution VUV beamline, range 25 – 240 eV
 - Resolving power 800 at 200 eV
 - ARUPS, LEED, Dual-anode X-ray source
 - XAS measurements
 - Omicron EA-125 photoelectron analyzer for ARUPS and XPS
 - View High-throughput Toroidal Grating Beamline for Photoelectron Spectroscopy at CAMD for more details.
 - Orhan Kizilkaya, orhan@lsu.edu
 
Infrared Spectromicroscopy Beamline (IR), Port 1A, 50 mrad
- Nicolet FT-IR spectrometer and Microscope, range 400 – 11700 cm-1
 - Transmission and reflection modes
 - Infrared 1D and 2D mapping with spatial resolution 10 µm
 - View The infrared microspectroscopy beamline at CAMD and its application in plant–pathogen interactions for more details.
 - Orhan Kizilkaya, orhan@lsu.edu
 
X-ray Techniques
- Energy range 7.0 - 15 keV with resolution of 3 eV, suitable for macromolecular crystallography, XANES, XRD
 - Amitava Roy, aroy1@lsu.edu
 
- Energy range 6.0 - 60 keV with energy resolution 1-3% and spatial resolution ~3 µm
 - X-ray phase contrast imaging - Talbot Laue interferometry - radiograph, phase-contrast, dark-field imaging
 - Kyungmin Ham, kham1@lsu.edu
 
SAXS - Small Angle X-ray Scattering Beamline
- Double-crystal monochromator with energy range from ~5-11KeV
 - Online 200mmx200mm multiwire gas detector
 - Sample to detector distance adjustable from 0.9m to 4.9m
 - View SAXS for further details.
 - Miriam Siebenbuerger, msiebenbuerger@lsu.edu
 
X-ray Absorption Spectroscopy Beamlines
- LEXAS: Low Energy X-ray Absorption Spectroscopy
Energy range: 1.2 – 1.8 keV - DCM: Double Crystal Monochromator Beamline
Energy range: 1.8 – 6 keV - WDCM: Wavelength Shifter XAS
Energy Range: 7 – 18 keV - HEXAS: High Energy X-ray Absorption Spectroscopy
Energy range: 4.5 - 25 keV - PWX: MPW Probe with X-rays
Energy range: 6 – 14 keV - View X-ray Absorption Spectroscopy (XAS) for further details.
 - Amitava Roy, reroy@lsu.edu